LIB Industry Environmental Test Chambers

Temperature Humidity Test Chamber

Supply a large range of standard and custom temperature and humidity test chambers to suit many types of environmental test conditions. Our climate and humidity test chambers are available in a variety of sizes and configurations, ranging in size from 50 Liters to 3000 Liters, including bench tops, floor type and walk-in. Floor types have more than 26 models to achieve various tests. To perform temperature and humidity test, cold resistance test, thermal cycle test, ultra low temperature test, high temperature test, storage condition, and calibration function.

Steady Cooling

The compressor of the LIB test chamber can be turned on at 150°C. We specially designed a refrigeration bypass to prevent the compressor damage caused by the excessively high refrigerant temperature in the initial stage of cooling, which greatly improves the stability of the cooling.

PID Control

The main unit PID controller is to command, operate, detect and redistribute the various components of the equipment to high speed processing

Full Climate

Can achieve low temperature, high temperature, low humidity and high humidity environmental testing.

Network communication

The source code of the LIB control system can be opened to customers, which can match the operating software or connect to the lab WEB system

Save Water

The automatic water inlet system has realized water circulation and water resources saving, and also realized automated testing.

Multi-language controller display

Multiple languages can be selected, English, Chinese, Russian, Korean, German, French, Polish, Spanish, Turkish, Romanian.

Air Circulation

Circulating air enters the air from one side of the workroom, and air exits from the other side. The air circulates evenly, so that the temperature and humidity environment in the working room is evenly distributed.

Sample Shelf

The height of the shelf is adjustable and can be removed directly to facilitate the various sizes of test samples.

Cable Hole

A standard test hole, located at the one side of the work room, is provided with a sleeve inside to prevent moisture from entering the insulation layer.

A Variety of Models to Choose

Type: Benchtop, Floor Stand & Walk In. Size available 50L/80L/100L/225L/500L/1000L/1500L/2000L and more.

Standard and Custom

In addition to standard models, there are also customized chambers according to special requirements.

Remote Communication

Standard network port and USB interface are used for computer and smartphone remote control. The test data exported via USB flash drive can be download (CSV and excel format).

Viewing Window

Double layer insulating glass 8cm thickness, made of tempered glass. The conductive film is located on the interior glass to prevent window frosting, built-in LED light for the work room lighting ; can clearly observe samples.


Benchtop Environmental Test Chamber

Benchtop Temperature humidity Test Chambers are Small, bench-top test chamber for simulating temperature and humidity environments. Included only temperature, temperature and humidity test chambers. Widely used in electronics, automotive, manufacturing, research and laboratories. Its very good advantages are small, desktop, small footprint, portable, stable performance and Full function. A Benchtop Environmental Chamber offers flexibility, uniformity, and control accuracy.

Small and Affordable

The benchtop chamber is specially designed to meet the customer’s small space and small test specimens, and has a more competitive price.

Full functioning

Can perform precise testing of temperature only, temperature and humidity.

Quick ship

Popular models are in stock and can be shipped quickly in 3 days.

EMC Test

The calibration test chamber is EMC tested and will not cause electromagnetic interference to the tested electronic products.


Fast Change Rate Thermal Cycle Chamber

The rapid rate thermal cycle chamber is designed for testing specimens under the rapid temperature change. LIB TR models meet the ESS (Environment Stress Screen) test. The temperature ramp rate is controllable at 5℃ / 10℃ / 15℃ per minute.

Energy saving

When the temperature needs to be stabilized again, the advanced PID control can effectively control the output value of the constant phase
and the recovery phase.


Thermal Shock Test Chamber

LIB 2-zone hot cold thermal shock test chamber is available in small capacity and large capacity to meet different testing requirements. The specimen automatic transferred from cold chamber to hot chamber by basket. The basket slides vertically and smoothly through rails, to make the specimen is exposed to the two chambers.Thermal shock test chamber has upgraded to touch-screen controller with Ethernet, you are
easy to operate over network.

Quick Temperature Recovery

Thermal shock chamber has preheat room and pre-cool room, which achieves temperature recovery time within 5 minutes.

Elevator Transfer System

Pneumatically lift the basket, the moving time is within 3 seconds. The basket is equipped with a lifting track to ensure the stability
during moving.

Drain Water Inside Of Workroom

Condensation will occur during high and low temperature impact testing, and the condensed water generated in the workroom will be discharged in time, so as not to freeze and affect the test.


3-Zone Thermal Shock Test Chamber

LIB 3TS series thermal shock test chamber, it is just one chamber for test room, it circulates cold and hot air through the pneumatic damper on the left and right sides. This design makes external size smaller, and this 3TS series thermal shock chamber are pre-heated and pre-cooled to achieve faster test temperature.

Test Specimen Does Not Move

With the three-zone design, the test specimen does not need to be moved for thermal shock testing. It is very easy to place the test
specimens.

Suitable For Large Objects

Test area of 3TS chambers does not move. The size of the workroom is not limited by the size of the basket and is the actual size that can be used.

Can Observe The Changes
Of The Test Specimen

Designed with a transparent window made of reinforced tempered glass, you can view the changes of the test specimen in real time.


Cryogenic Chamber

LIB cryogenic chamber uses a mechanical compressor to cool to -120℃ , which replaces the traditional liquid nitrogen cooling method. The test chamber sizes are 100L, 225L, 500L, 800L, 1000L for choose. The temperature test range is-120 ℃ to 150 ℃ . It can be applied to various field for test by simulating extreme natural environments, to detect product substitution and performance stability.Mainly used in aerospace, military, electronic component testing and other high-precision fields, as well as highend processing industry quenching process.

Mechanical Refrigeration

Cryogenic chamber uses triple refrigeration, using combined refrigerants and mechanical refrigeration to control the temperature at -120℃.

Energy Saving

When the temperature needs to be stabilized again, the advanced PID control can effectively control the output value of the constant phase and the recovery phase.

Temperature Humidity Vibration Chamber

LIB THV Series vibration chambers combine temperature, humidity and vibration environmental conditions, which  consists of temperature humidity chamber and vibration shaker.

Simulate Up To 3 Combined Environmental Conditions In
One Chamber

Combined high and low Temperature, temperature/humidity and vibration system in one chamber. One-stop solution for customization, production.

Installation And Training

Customize the size, temperature, humidity and vibration  table according to customer requirements. Provide  one-stop solutions for design, production, installation,  commissioning and training.